Gas boiler vailant atmosphere tech pro. Heating systems for country and country houses. Boilers, gas water heaters, water heaters - Repair, service, operation. Recommendations for assembly and installation. Other faults and how to fix them

2017-03-22 Evgeny Fomenko

Features of operation and diagnostics

During the connection, operation and maintenance of the Vaillant gas heating boiler, some malfunctions may occur. Models in which an electrical control system with a screen is installed makes it possible to understand what exactly does not work in a given situation.

To understand what to do in certain cases, consider the common error codes of the Vilant gas boiler, and what needs to be done if they occur. If several errors have occurred at once, they are displayed alternately for about 2 seconds.

Icon designations can start with the letter F (error) or S (status). Specifications and codes that are inherent in each specific model are spelled out in the operating instructions.

The most common error codes for Vilant boilers

F5

Error F5 means a rupture of the external flue gas sensor. Possible causes include incorrect operation of the flue gas sensor, disconnected plug or damaged cable, or incorrectly fitted spare resistor. The code is valid only for the mounted Vailant Atmo model.

5ER

If the display alternates between the water temperature and the 5ER (or SER) error, this is a reminder that it's time to spend maintenance devices.


The user himself can set the frequency of how often this reminder pops up. The value in the item for diagnostics D.084 is set in the range from 0 to 3000 hours with an interval of 10 hours (the number 300 corresponds to 3000 hours). To completely disable this function, enter “---“ instead of a numeric value.

F15

Fault F15 indicates a short circuit in the outdoor flue gas sensor. Presumably, there was a short circuit with the sensor plug body, a short circuit inside the harness with wires, or the sensor itself is faulty. Shown only in Vaillant Atmo wall-hung boilers.

F20

Error F20 (F20) detects that a protective shutdown of the device has occurred due to the fact that the safety limiter of the STB temperature indicator has worked. It triggers when the maximum permissible temperature is exceeded.

This may happen due to the fact that the ground contacts of the wiring harness with the housing are incorrect, breakdown of the NTC return or supply line (weak contact). A breakdown through the ignition wire, electrode or ignition plug is also possible.

F21

Error F21 means emergency shutdown of the flame supervision machine GFA.


F22

Error F22 (F22) indicates operation protective shutdown due to insufficient water. The reasons for this are a malfunction of the pump cable or toggle switch with an insufficient amount of water, the pump does not work or is blocked, or it has too little power.

F23

Error F23 detects an emergency shutdown due to a too large temperature difference between the sensors located on the supply and discharge lines.

  • Very low pump powerwhy the pressure on one side drops;
  • pump blocked;
  • return and direct line NTC sensors are not in their places.

F24

Error F24 signals an emergency shutdown if the temperature rises too quickly. This means the presence of air in the device, reduced pump performance, blockage or very low pressure in the heating system. The gravity valve may be incorrectly connected or blocked.


F26

Error F26 means that the flow of the gas valve is not detected stepper motor due to breakdown of gas fittings. It may be that the servomotor of the gas fittings is not connected or the servomotor of the gas fittings is broken, the connector is incorrectly inserted into the board, or there is a break in the wiring harness.

F28

Error F28 (F28) indicates that the equipment did not turn on, a malfunction occurred when the device was started, and the ignition attempts were unsuccessful.

There are a number of options:


Boiler ignition electrode
  • electronics malfunctioneg interruption of the ionization current.
  • F29

    Error F 29 (F29) expresses that the burner flame goes out during operation and further attempts to ignite are unsuccessful. Fuel supply may be temporarily interrupted, ignition transformer interrupted, or equipment improperly grounded.

    F33

    Error F33 (F33) reflects that the device for measuring pressure force does not turn on. After switching off the fan, the pressure switch does not disconnect the contact. Relevant for the Vilant Turbo TEK PRO line.

    S33

    Error S33 indicates that the device is locked and put into a 20-minute standby state, the heat exchanger frost protection mode has been activated. The reason is that the contacts of the relay of the air-gas path have not been connected. This condition can appear in the Vilant 242 Turbo double-circuit boiler.

    Gas boiler Vaillant turboTEC PRO 242

    F36

    Error F36 (F36) - the thrust rollover sensor has recognized the release of combustion products. Indicates that the traction is too weak. Most likely, the chimney is clogged or the ventilation is closed. The elimination of this problem consists in cleaning the chimney, turning off the active hood over the stove and opening the window.

    F37

    Error F 37 (F37) means deviation of the fan speed (too fast or slow). The pressure sensor may be broken.

    F38

    Error F38 means that the fan is out of order and needs to be replaced.

    F53

    Error F53 indicates incorrect combustion settings.

    Possible reasons:


    F61

    Error F61 indicates an error in the control of the gas valves. The cable harness connection may be damaged and a short circuit has occurred, the gas valve or the electronic board is faulty.

    F62

    Error F62 - delayed time for turning off the gas valve. It can be triggered if there is an extraneous light inside (the control electrode does not indicate flame attenuation).

    F71

    Fault F71 indicates a failure of the flow temperature sensor. It is probably defective or at a great distance from the supply line.

    F72

    Error F72 appears when the return or flow temperature sensor fails. It may be defective or a very large temperature difference in the direct or return line of the NTC sensors.

    F75

    Error F75 (F75) means that there is no pressure jump when the pump is turned on. There may be oxygen in the heating system or the pump or water sensor is not working correctly. To rectify the situation as soon as possible, the adjustable bypass is checked, an expansion tank is connected to the return line.

    Gas boiler pump

    SER

    The SER error is the same as the 5ER code (the letter "S" and the number "5" are displayed the same on the electronic display). After the problem has been eliminated, the errors are reset after pressing the "Reset" button or switching the boiler on and off from the network.

    Other faults and how to fix them

    If the reverse thrust diode blinks, then either it is faulty, or the combustion products are not completely removed, but enter the room. The repair instructions in this case are as follows: first, you should clean the chimney, then check the quality of ventilation.

    The return flow sensor can then be replaced. Initially, during installation, it is important to comply with all safety requirements. Quite often the gas burner gets clogged, soot is deposited on it. It should be cleaned regularly to fully control the flame level.

    Vaillant (Vailant)VUW 240 / 5-3atmoTECpro is a modern atmospheric gas boiler wall typehoused in an elegant, robust housing and equipped with intelligent controls. The versatility of the unit under consideration allows you to effectively use it in any conditions to create the most comfortable living conditions.

    Features and advantages of Vaillant wall-mounted gas boilers of the atmoTEC & turboTEC pro series

    - Description

    • Wall-mounted gas heater with integrated preparation of domestic hot water
    • The power of the device is regulated by a modulating burner
    • Temperature control hot water
    • Automatic switching to the mode of preparation of domestic hot water at its consumption from 1.5 l / min. and control of the power of the apparatus depending on the flow rate and temperature of the heated water
    • Forced exhaust of combustion products through a certified flue / air duct system (for turboTEC pro)

    - Installation possibilities

    • Heating and built-in hot water supply
    • Suitable for reconstructed and under construction residential buildings and apartments where it is impossible to install a conventional chimney
    • Can be installed in a residential area
    • The minimum required side clearance is 10 mm, all nodes are accessible from the front
    • NOT USED IN CASCADE UNITS

    - Equipment

    • Backlit liquid crystal display, push-button control
    • Internal software for status monitoring, parameter setting and troubleshooting
    • Built-in flow plate heat exchanger for water heating
    • Integrated circulation pump, closed expansion vessel, automatic air vent, automatic adjustable bypass valve, safety valve, motorized priority diverter valve
    • "Intelligent" pressure control in the heating system
    • Primary copper heat exchanger with average efficiency\u003e \u003d 91%
    • Chromium-nickel steel burner
    • Permanent frost protection
    • Anti-seizing pump and three-way valve
    • WINTER / SUMMER switch
    • Possibility of setting to partial power in heating mode
    • Electronic ignition and control of all functions
    • Connection set included in delivery
    • Integrated switching module for eBus interface

    Modern heating boilers The Vaillant atmoTEC & turboTEC pro series are perfect for creating comfortable heating for homes. The lineup represented by units of various capacities and cover a wide range of possible serviced areas. All devices are equipped with modulating burners, which allow you to regulate the heating power, which determines the efficiency of the boilers.

    Description

    Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE is a double-circuit wall-mounted gas boiler designed for heating and hot water supply of residential premises. The universal model can be installed as in an ordinary apartment, and a cottage or country house, including directly in the room. High level safety and automatic control systems make it possible to install the boiler in almost any convenient place.

    In 2015, Vaillant renewed these boilers, which had been recognized leaders in the market for 8 years. heating equipment in its class. The main functions of the boiler and the control system were modernized, which made its operation even more convenient and efficient. Among the key changes that have been made to the design and technical equipment of the Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE boiler:

    • updated performance - refined and modern designthat attracts attention;
    • a new electronic control panel - an alphanumeric display with bright backlight, which shows the readings of the pressure gauge and other parameters;
    • improved self-diagnostic systems - the number of information codes that are assigned has increased possible reasons boiler malfunctions;
    • commissioning has become even easier due to the possibility of flexible adjustment of the unit to work with a specific heating system;
    • unpretentiousness to the quality of water - the installed impeller of the circulating pump with diamond coating allows you to work, including on contaminated liquid.

    Advantages of the boiler Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE

    Among the distinguishing features of this unit are laconic and stylish design, ergonomic design, convenient system management. Like other Vaillant wall-mounted gas boilers, all the main units of the unit and regulators are accessible on the front panel, which greatly facilitates use. Built-in plate flow heat exchanger will provide fast heating limescale-free water even over a long service life.

    The operation of the main elements of the Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE boiler is fully controlled by automation: the unit is equipped with protection systems for the boiler circuit emptying, protection against freezing and pump jamming. Installed microprocessors control the internal operating system, reliably protecting it from possible failures. In addition, the boiler board has a voltage stabilizer that protects it from power surges.

    Electronic ignition will ensure easy activation of the boiler, during operation it is possible to switch to partial power mode to reduce energy consumption. At a consumption of 1.5 liters per minute, the boiler automatically switches to the mode of preparation of domestic hot water.

    The safety level of Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE is one of the highest among wall-mounted gas boilers of a similar class. The self-diagnosis system analyzes the main indicators and, if necessary, displays information about possible malfunctions. Additional sensors are sensitive to the lack of draft in the chimney and to the detection of back draft.

    The Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE boiler is equipped with:

    • circulation pump;
    • closed expansion tank;
    • gas automatics with electronic ignition;
    • automatic air vent;
    • adjustable bypass and safety valve;
    • modulating burner made of chromium-nickel steel;
    • a switch of the "winter-summer" modes, a pressure gauge.

    You can find out more information about this model by downloading the documentation or from the sales team. You can buy a wall-mounted gas boiler Vaillant atmoTEC PRO VUW 240 / 5-3 (240 / 3-3) H-RU / VE on our website or place an order with our managers. You can also use the service

    The wall-mounted double-circuit gas boiler Vaillant atmoTEC pro VUW 240 / 5-3 with natural smoke exhaust is designed for heating living quarters and preparing hot water. It is equipped with a modulating burner and an intelligent control system. Features and advantages of the model:

    • Copper primary heat exchanger;
    • Burner made of chromium-nickel steel;
    • Built-in security systems;
    • Built-in strapping;
    • Possibility of connecting a thermostat.

    The boiler is suitable for use in private households and apartments with chimneys.

    The Vaillant atmoTEC pro VUW 240 / 5-3 double-circuit gas boiler is built according to the classical scheme with two separate heat exchangers. The primary heat exchanger is made of copper, the plate secondary is made of stainless steel. The burner is made of steel with the addition of chromium and nickel, which makes it more resistant to thermal stress. Thanks to a thermal power of 24 kW, the boiler can heat rooms up to 240 sq. m with a maximum gas consumption of 2.8 cubic meters. m / hour - thus saving on utilities... The hot water supply capacity is 11.5 l / min, which is enough for two taps.

    On board the Vaillant atmoTEC pro VUW 240 / 5-3 gas double-circuit boiler there is equipment for the full operation of the heating circuit. An expansion tank for 6 liters of coolant, a silent circulation pump, a safety valve and an automatic air vent are installed here. There are also systems of protection against overheating, control of the presence of a flame, protection against blocking of the circulation pump. The electronics ensure safety and are responsible for the modulation of the flame - thanks to this, the boiler strictly maintains the temperature of the coolant and hot water (the result will be a comfortable shower).

    The boiler is designed to work in heating systems closed type with forced circulation of the coolant. The pressure in the heating circuit is up to 3 bar, in the DHW circuit up to 10 bar. The temperature in the system is regulated within + 30-85 degrees, hot water - from +35 to +65 degrees. Control is carried out by means of a keypad, for parameter control there is an LCD display with night illumination. Thanks to the simple user interface, even an unprepared user can handle the control - select the temperature and the boiler will do the rest. It is also recommended to connect a thermostat to it - it independently maintains the set temperature using the built-in sensor and saves up to 10-15% of gas.

    You can buy a wall-mounted double-circuit gas boiler Vaillant atmoTEC pro VUW 240 / 5-3 from a brand with a worldwide reputation in the Teplodvor online store. The boiler is supplied with chimney sections, room thermostats, convectors and much more. Delivery geography - Moscow and all of Russia, pickup from the warehouse is also possible.